Safety Valve with Differential Piston SiZ 2507

Function


 Protecting the system against excessive pressure

Application


 Conventional power stations: drum, superheater, reheater
 Nuclear power stations:steam generator protection on the secondary side

Design


 
Construction:
angel-type valve
 
Size:
DN 50 - 300
 
Connections:
weld end inlet and outlet, flange possible
 
Seat-Ø:
GS, CrMo
 
Max. set pressure:
280 bar
 
Control:
pneumatic PC 53 or PC 50
 
Function:
+5% / -7%
 
Materials:
GS, CrMo
 
Mounting position:
vertical
 
Perm. temp.:
560°C
 
In case of a breakdown of the auxiliary energy function as self-operated spring loaded safety valve

 
Integrated pneumatic piston as differential piston

 
Easily accessible for service operations by lifting off the complete upper part of the valve at the bayonet fixing

 
Belleville spring with spherical centering

 
Compact design

 


Approvals


 TÜV-Type Test Approval

Technical Data Sheet


 Data Sheet SiZ 2507