Safety Valve with System Medium Control SiH 3112

Function


 Protecting the systems against excessive pressure

Application (nuclear power stations) Type pressurized water reactor


 Bypass of the low pressure turbine
 Pressure retainer - relief valve
 Primary cycle-Safety valve

Design


 
Construction:
angel-type valve
 
Size:
DN 100 - 700
 
Seat-Ø:
63 - 500 mm
 
Max. set pressure:
160 bar
 
Opening time:
100 - 200 ms
 
Function:
main valve with system medium in accordance with the load principle
 
Materials:
GS, CrNiMo
 
Mounting position:
vertical
 
Type boiling water reactor

 
Live steam protection

 
Bypass of the low pressure turbine

 
High tightness until reaction

 
Load principle of operation by system medium with long opening times

 
Actuation by several different, independent control valves

 