HP-Bypass Station with Safety Function SiRA BH (with Parabolic Disc and Spindle Injection)

Function


 Protection of the high pressure section of steam boilers against excessive pressure
 Pressure and temperature control

Application


 Safety valve for the high pressure section of the boiler
 Turbine Bypass for starting up and stopping steam generators and in case of failures

Design


 
Construction:
angular- /Z-form
 
Seat-Ø:
72 - 160 mm
 
Capacity:
K-values from 160 m3/h until 800 m3/h
 
Body:
forged, materials and pipe connection in accordance with customer specification (T-piece for pipe can also be supplied)
 
Injection:
via spindle
 
Throttling:
controlled/uncontrolled
 
Characteristic:
linear
 
Actuator:
hydraulic
 
Leakage rate:
DIN 3230 part 3 - leakage rate 1
as well as ANSI/FCI 70-2
Class V possible
 
Mounting position:
vertical, horizontal and hanging

 



Copyright © 2005 Bopp & Reuther Sicherheits- und Regelarmaturen | Impressum/Disclaimer | Sitemap | Design by net-solution


Bopp & Reuther Sicherheits- und Regelarmaturen GmbH, Carl-Reuther-Straße 1, D-68305 Mannheim
Geschäftsführer: Dipl. Ing. Christel Halm-Schmidt
Sitz der Gesellschaft: Mannheim, HRB 5074, Steuer-Nr. 35001/03156, UstId-Nr. DE 811115106
E-Mail: Sales@SR.BoppuReuther.com, Tel. +49 (0)621 / 749-0, Fax: +49 (0)621 / 749-1604