HP-Bypass Station with Safety Function SiRA BHT (with Parabolic Disc and Atomized Steam Injection)
Function
Protection of the high pressure section of steam boilers against excessive
Pressure and temperature control
Application
Safety valve for the high pressure section of the boiler
Turbine Bypass for starting up and stopping steam generators and in case of failures
Design
Construction:
angular-/Z-form
Seat-Ø:
72 - 160 mm
Capacity:
K-values from 160 m3/h until 800 m3/h
Injection:
secondary atomized steam injection
Throttling:
controlled/uncontrolled
Actuator:
hydraulic
Characteristic:
linear
Body:
forged, materials and pipe connection in accordance width customer specification (T-piece for pipe can also be supplied)
Leakage rate:
DIN 3230 part 3 - leakage rate 1
as well as ANSI/FCI 70-2
Class V possible
Mounting position:
vertical, horizontal and hanging