High Pressure Reducing Valve DRE

Function


 Pressure and rate control for steam generators

Application


 High pressure start-up reducing station

Design


 
Construction:
angular/Z-form
 
Seat-Ø:
28 - 200 mm
 
Capacity:
K-values from 8 m3/h until 800 m3/h
 
Throttling:
controlled/uncontrolled
 
Actuator:
hydraulic, electrical or pneumatic
 
Characteristic:
linear/equal percentage
 
Body:
forged, materials and pipe connection in accordance with customer specification
 
Leakage rate:
DIN 3230 part 3 - leakage rate 1
as well as ANSI/FCI 70-2
Class V possible
 
Mounting position:
vertical, horizontal and hanging

 



Copyright © 2005 Bopp & Reuther Sicherheits- und Regelarmaturen | Impressum/Disclaimer | Sitemap | Design by net-solution


Bopp & Reuther Sicherheits- und Regelarmaturen GmbH, Carl-Reuther-Straße 1, D-68305 Mannheim
Geschäftsführer: Dipl. Ing. Christel Halm-Schmidt
Sitz der Gesellschaft: Mannheim, HRB 5074, Steuer-Nr. 35001/03156, UstId-Nr. DE 811115106
E-Mail: Sales@SR.BoppuReuther.com, Tel. +49 (0)621 / 749-0, Fax: +49 (0)621 / 749-1604