| Pressure and rate control for steam generators
|
| High pressure start-up reducing station
|
|
Construction:
|
angular/Z-form
|
|
Seat-Ø:
|
28 - 200 mm
|
|
Capacity:
|
K-values from 8 m3/h until 800 m3/h
|
|
Throttling:
|
controlled/uncontrolled
|
|
Actuator:
|
hydraulic, electrical or pneumatic
|
|
Characteristic:
|
linear/equal percentage
|
|
Body:
|
forged, materials and pipe connection in accordance with customer specification
|
|
Leakage rate:
|
DIN 3230 part 3 - leakage rate 1
as well as ANSI/FCI 70-2
Class V possible
|
|
Mounting position:
|
vertical, horizontal and hanging
|
|
|
|